- This tank design is a one piece unit. Top is sealed with a fibrous mastic sealant
- Tanks conform to National Standards of Canada CAN/CSA B66-16
Notes
1. Inlet contains one 100mm flexible rubber connection
fitted with a 100mm baffle tee
2. Outlet contains one 100mm flexible rubber
connection fitted with Tuf-tite EF-6 Effluent Filter
3. Cast in place 610mm ID Tuf-tite riser with dome lid
secured with stainless steel fasteners
4. Two 150mm x 150mm partition flow throughs
Holding Tanks Features
Concrete Strength
Minimum standard for our Industry is 28 MPa over 28 Days, our strength reports are almost double the minimum.
The pipes that go into the tank have to be watertight. We cast our tanks with flexible connections that are easy to seal and allow 15 degrees of deflection.